Maintenance GV 7000A / 7003A
32 wc_tx001625gb.fm
5 Maintenance
5.1 Periodic Maintenance Schedule
The table below lists basic machine maintenance. Tasks designated
with check marks may be performed by the operator. Tasks
designated with square bullet points require special training and
equipment.
Daily
before
starting
After
first
20 hrs.
Every
50
hrs.
Every
100
hrs.
Every
300
hrs.
Check fuel level.
3
Check engine oil level.
3
Inspect air filter. Replace as needed.*
3
Check external hardware.
3
Clean air cleaner element.*
3
Inspect shockmounts for damage.
3
Change engine oil.*

Check and clean spark plug.
Check and adjust valve clearance.
Clean fuel tank.*
Check condition of fuel line. Replace
when necessary.
*Service more frequently in dusty conditions.