GP/GPS 5600A Maintenance
42
3.14 Electrical Schematic (CAN models only)
Ref. Description Ref. Description
A Generator D Wacker Engine
B Control box E Honda Engine
C Electric start engines (GPS)
Ref. Description Ref. Description
1 Main stator winding 1 13 Rectifier
2 Main stator winding 2 14 Rotor winding/brushes
3 Auto idle unit 15 Secondary (excitation) winding
4 Main circuit breaker 16 DC winding
5 Voltage selector switch
(120/240V position shown)
17 Automatic voltage regulator (AVR)
6 Duplex receptacle—120V 18 15A fuse (GPS only)
7 Twist-lock receptacle—120V 19 Ignition switch (GPS only)
8 Twist-lock receptacle—120/240V 20 GFCI
9 Auto idle switch 21 20A circuit breaker
10 5A fuse 22 20A circuit breaker
(GP 3800 CAN and GP4000 only)
11 Capacitor 23 30A circuit breaker
(GP 5600/6600 CAN only)
12 Engine ON / OFF switch 24 Neutral bond wire