Operation GP 2500A
wc_tx000447gb.fm 20
5.5 Grounding the Generator
See Graphic: wc_gr000544
A ground connection (a) is located on the generator frame. For proper
operating safety, this ground terminal must be connected to a good
ground source. This ground connection must comply with National
Electrical Code standards, and state and local regulations.
5.6 Operating Heavy Loads
Limit operations requiring the maximum rated output of 2500 Watts to
20–30 minutes. For continuous operation, do not exceed the
continuous rated output of 2250 Watts.
CAUTION: DO NOT exceed the current limit specified on the control
panel for any receptacle.