Wacker Neuson Cub 200 Návod k obsluze

Procházejte online nebo si stáhněte Návod k obsluze pro Ohřívače prostoru Wacker Neuson Cub 200. Wacker Neuson Cub 200 Operator`s manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 -

0192822 001 11100192822Operator’s ManualIndirect-Fired Air HeatersHI 110D / HI 110HD DHI 200D / HI 200HD DHI 300D / HI 300HD D

Strany 2

Safety Information HI 110 / 200 / 30010 ghi_si000463gb.fmMachine installation guidelinesAs a recommended install

Strany 3 - Foreword

HI 110 / 200 / 300 Safety Informationghi_si000463gb.fm 111.5 Safety Guidelines for Maintaining the MachineLicensing/training/ Only trained personnel

Strany 4

Safety Information HI 110 / 200 / 30012 ghi_si000463gb.fm Safety glasses with side shields Hearing protection

Strany 5

HI 110 / 200 / 300 Labelsghi_si000464gb.fm 132 Labels2.1 Label Locationsghi_gr007386AACCEF(4)(4)BJJBGHKHKLLDGHHAAFCCEBBGDGNNHI 110HI 200

Strany 6

Labels HI 110 / 200 / 30014 ghi_si000464gb.fmHI 300(4)AAFCCEBBJHKLDG Hwc_gr007556N

Strany 7 - 1 Safety Information

HI 110 / 200 / 300 Labelsghi_si000464gb.fm 152.2 Label MeaningsA WARNINGHot surface hazard!B WARNINGEntanglement hazard. Rotating machinery. Do not re

Strany 8

Labels HI 110 / 200 / 30016 ghi_si000464gb.fmG DANGERUsing a heater indoors can kill you in minutes. Heater exha

Strany 9

HI 110 / 200 / 300 Labelsghi_si000464gb.fm 17M WARNINGLicensed gas technician required.Natural gas / liquid propane burner setup and installation, fue

Strany 10

Lifting and Transporting HI 110 / 200 / 30018 ghi_tx001446gb.fm3 Lifting and Transporting3.1 Lifting and Transpo

Strany 11

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 194 Operation4.1 Installing the Lift Brackets (if equipped)Before attempting to lift the machine, the li

Strany 12

Copyright notice© Copyright 2010 by Wacker Neuson Corporation.All rights, including copying and distribution rights, are reserved.This publication may

Strany 13 - HI 110 / 200 / 300 Labels

Operation HI 110 / 200 / 30020 ghi_tx001447gb.fm4.2 Installing the Wheels and HandleOverviewThe axle, wheels, ha

Strany 14 - Labels HI 110 / 200 / 300

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 214.3 Controls and Service LocationsHI 110DHI 200 / 300

Strany 15

Operation HI 110 / 200 / 30022 ghi_tx001447gb.fmMachine componentsHI 300 HDwc_gr007557Ref Description Ref Descri

Strany 16

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 234.4 Control PanelControl panel componentsSymbols and meaningsRESETRef Description Ref DescriptionaBurn

Strany 17

Operation HI 110 / 200 / 30024 ghi_tx001447gb.fm4.5 Recommended FuelsLow ambient temperatures cause diesel fuels

Strany 18 - 3 Lifting and Transporting

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 254.7 Positioning the MachineGuidelinesObserve the following guidelines when positioning the machine for

Strany 19 - HI 110 / 200 / 300 Operation

Operation HI 110 / 200 / 30026 ghi_tx001447gb.fm4.8 Suggested VentingWhen installing vents: Do not use B-vent e

Strany 20 - Operation HI 110 / 200 / 300

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 27Note: The above venting diagram shows suggested venting layouts only. Consult all appropriate governin

Strany 21

Operation HI 110 / 200 / 30028 ghi_tx001447gb.fm4.9 Installing the Heater DuctOverviewOptional ducts can be conn

Strany 22

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 294.10 Connecting Power to the MachineRequirements Power source (115VAC) Machine properly positioned

Strany 23

Forewordghi_tx001445gb.fm 3ForewordThis heater is designed and approved for use as a construction heater in accordance with the applicable standards o

Strany 24

Operation HI 110 / 200 / 30030 ghi_tx001447gb.fm4.11 Pre-Starting ChecksRequirements Machine properly positione

Strany 25

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 314.12 Starting the MachineRequirements Machine properly positioned Power connected Pre-Starting Chec

Strany 26

Operation HI 110 / 200 / 30032 ghi_tx001447gb.fm4.13 Starting the Machine in Extremely Cold WeatherBackgroundIn

Strany 27

HI 110 / 200 / 300 Operationghi_tx001447gb.fm 334.14 Stopping the MachineProcedureFollow the procedure below to stop the machine.1. Turn the operation

Strany 28

Operation HI 110 / 200 / 30034 ghi_tx001447gb.fm4.16 Installing and Using the Remote ThermostatRequirements Rem

Strany 29

HI 110 / 200 / 300 Accessoriesghi_tx001448gb.fm 355 Accessories5.1 Available AccessoriesIntroductionWacker Neuson Corporation offers many optional acc

Strany 30

Burner Setup HI 110 / 200 / 30036 ghi_tx001449gb.fm6 Burner Setup6.1 Removing the Access PanelRequirements Mach

Strany 31

HI 110 / 200 / 300 Burner Setupghi_tx001449gb.fm 376.2 Removing and Installing the Burner AssemblyRequirements Machine shut down and cooled Machine

Strany 32

Burner Setup HI 110 / 200 / 30038 ghi_tx001449gb.fm6.3 Setting Up the BurnerFactory settingsBackgroundThe burner

Strany 33

HI 110 / 200 / 300 Burner Setupghi_tx001449gb.fm 397. Conduct a smoke spot test. Follow the smoke spot tester manufacturer’s instructions and the gene

Strany 34

Foreword4 ghi_tx001445gb.fmManufacturer’s approvalThis manual contains references to approved parts, attachments

Strany 35 - 5.1 Available Accessories

Burner Setup HI 110 / 200 / 30040 ghi_tx001449gb.fm6.4 Checking the Oil Burner ElectrodesRequirements Machine s

Strany 36 - 6.1 Removing the Access Panel

HI 110 / 200 / 300 Burner Setupghi_tx001449gb.fm 416.5 Checking/Changing the Burner NozzlePrerequisites Machine shut down and cool to the touch Mach

Strany 37 -  Machine properly positioned

Burner Setup HI 110 / 200 / 30042 ghi_tx001449gb.fm6.6 Adjusting the Fuel PressureRequirements Machine shut dow

Strany 38 - 6.3 Setting Up the Burner

HI 110 / 200 / 300 Burner Setupghi_tx001449gb.fm 43Adjusting fuel pressure8. Adjust the fuel pressure if necessary using the adjusting screw (e) and r

Strany 39 - HI Heater

Maintenance HI 110 / 200 / 30044 ghi_tx001450gb.fm7 Maintenance7.1 Periodic Maintenance ScheduleTaskInterval*(ho

Strany 40 -  Burner cool

HI 110 / 200 / 300 Maintenanceghi_tx001450gb.fm 457.2 Changing the Fuel Heater FilterPrerequisites Machine shut down Burner coolProcedureFollow the

Strany 41

Maintenance HI 110 / 200 / 30046 ghi_tx001450gb.fm7.3 Inspecting and Cleaning the Cadmium (CAD) CellPrerequisite

Strany 42 -  Fuel pressure gauge

HI 110 / 200 / 300 Maintenanceghi_tx001450gb.fm 477.4 Cleaning the Fan Blades and MotorPrerequisites Machine shut down and cool to the touch Power s

Strany 43 - 6.7 Setting the Air Band

Maintenance HI 110 / 200 / 30048 ghi_tx001450gb.fm3. Inspect and, if necessary, clean the motor (m) using compre

Strany 44 - 7 Maintenance

HI 110 / 200 / 300 Maintenanceghi_tx001450gb.fm 497.6 Inspecting the Flame HeadPrerequisites Machine shut down and cool to the touch Machine properl

Strany 45

HI 110 / 200 / 300 Table of Contentswc_bo0182002en_002TOC.fm 5Foreword 31 Safety Information 71.1 Signal Words Found in this Manual ...

Strany 46

Maintenance HI 110 / 200 / 30050 ghi_tx001450gb.fm7.7 Inspecting the Electrical ConnectionsAfter disconnecting t

Strany 47 - HI 110D HI 200 / HI 300

HI 110 / 200 / 300 Maintenanceghi_tx001450gb.fm 517.9 List of AbbreviationsAmp ampere (unit of electrical current)asl above sea levelBTU British Therm

Strany 48 -  Power source disconnected

Maintenance HI 110 / 200 / 30052 ghi_tx001450gb.fmNotes:

Strany 49 - 7.6 Inspecting the Flame Head

HI 110 / 200 / 300 Basic Troubleshootingghi_tx001468gb.fm 538 Basic TroubleshootingNote: The following symptoms and remedies are some of the more com

Strany 50

Technical Data HI 110 / 200 / 30054 ghi_td000400gb.fm9 Technical Data9.1 Machine Technical DataModelHI 110DHI 11

Strany 51 - 7.9 List of Abbreviations

HI 110 / 200 / 300 Technical Dataghi_td000400gb.fm 55ModelHI 300DHI 300HD DUnitsHeat input BTU/hr 293,982 293,982Heat output BTU/hr 245,475 245,475A

Strany 52

Schematics HI 110 / 200 / 30056 ghi_tx001469gb.fm10 Schematics10.1 Schematic—HI 110 D12PE7352111014RDG/VRDRDRDRD

Strany 53 - 8 Basic Troubleshooting

HI 110 / 200 / 300 Schematicsghi_tx001469gb.fm 5710.2 Components—HI 110No. Description No. Description1 Fuse 7 Electric pilot lamp2 Overheat thermosta

Strany 54 - 9.1 Machine Technical Data

Schematics HI 110 / 200 / 30058 ghi_tx001469gb.fm10.3 Schematic—HI 110 HD D12PE7352111014RDRDRDRDRDRDWHBKWHWHWHW

Strany 55 - HI 300HD D

HI 110 / 200 / 300 Schematicsghi_tx001469gb.fm 5910.4 Components—HI 110 HD DNo. Description No. Description1Fuse 8Control2 Overheat thermostat 9 Room

Strany 56 - Schematics HI 110 / 200 / 300

Table of Contents HI 110 / 200 / 3006 wc_bo0182002en_002TOC.fm6 Burner Setup 366.1 Removing the Access Panel .

Strany 57 - HI 110 / 200 / 300 Schematics

Schematics HI 110 / 200 / 30060 ghi_tx001469gb.fm10.5 Schematic—HI 200 D / HI 300 D13PE731412152111014J1J4J3J2gh

Strany 58

HI 110 / 200 / 300 Schematicsghi_tx001469gb.fm 6110.6 Components—HI 200 D / HI 300 DNo. Description No. Description1 Fuse 8 Electric pilot lamp2 Tran

Strany 59

Schematics HI 110 / 200 / 30062 ghi_tx001469gb.fm10.7 Schematic—HI 200 HD D / 300 HD D14PE731512152111014J1J4J3J

Strany 60

HI 110 / 200 / 300 Schematicsghi_tx001469gb.fm 6310.8 Components—HI 200 HD D / 300 HD DNo. Description No. Description1 Fuse 10 Room thermostat plug2

Strany 61

Wacker Neuson SE · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02-0 · Fax: +49 - (0)89-3 54 0

Strany 62

HI 110 / 200 / 300 Safety Informationghi_si000463gb.fm 71 Safety Information1.1 Signal Words Found in this ManualThis manual contains DANGER, WARNING,

Strany 63

Safety Information HI 110 / 200 / 3008 ghi_si000463gb.fm1.2 Machine Description and Intended UseMachine descript

Strany 64

HI 110 / 200 / 300 Safety Informationghi_si000463gb.fm 91.3 Safety Guidelines for Operating the MachineOperator trainingBefore operating the machine:

Komentáře k této Příručce